Faulty ignition (Push button ignition)
Customer states no ignition to burner/s
NO
YES
YES
NO
YES NO
YES NO
Is more than one
burner affected?
Can customer see a
spark at the burner?
Send engineer and
order electrode
Ask customer to clean
and make sure burner
skirt and cap are fitted
correctly. Did this
work?.
Are all four
burners affected
Has customer check
electric supply to
hob?
Send engineer and
order ignition switch
and spark generator
Send engineer order
electrodes required and
possibly a spark generator