5
B) THERMOCOUPLES
REMOVE THE HOTPLATE AS IN STEP 2
REMOVE THE 7mm SECURING NUT
AND REMOVE THE THERMOCOUPLE
FROM THE BURNERBOWL
DISCONNECT FROM THE GAS TTAP
AND REMOVE THE THERMOCOUPLE
C) MICROSWITCHES
REMOVE THE HOTPLATE AS IN STEP 2
GENTLY EASE THE MICROSWITH OFF
THE GAS TAP
DISCONNECT FROM THE IGNITION
GENERATOR
NB THE INDIVIDUAL MICROSWITCHES CANNOT BE EXCHANGED
THEY MUST BE EXCHANGED AS A COMPLETE SET